Scheme/market | No. | Ex-Installation Manual |
---|---|---|
ATEX Certificate | TÜV 18 ATEX 8218X (2018) | DE, EN, FR, HR |
IECEx Certificate | TUR 18.0023X (2018) | EN |
EAC-Ex TUR Report | TC RU C-DE.HA65.B.01652/22 | RU |
INMETRO Certificate | TÜV 23.0363 X | PT |
MASC Certificate | MS/18-3256X | EN |
UKEX Certificate | TÜV 22 UKEX 7137 X | EN |
PESO Certificate | EN | |
KOSHA (KCs) | actually not available | KOR |
OSHA | ML1112007038U1 | ZH |
Marking and Labeling
Model Key: T08-VA2.2.K4.BOR-L.H-000.X-X
PN: 22070443
Certification
Camera-Series T08
Ex-Marking ExCam
Model Key: T08-VA2.2.K4.BOR-L.H-000.X-X
PN: 22070443
Serial no.: from PT0806221*
Prod. Year: from 2024
PS: PoE C3, Typ.: 4.5W, Max.: 7.2W
Temp. Range: -30°C < Tamb < +50°C
Prot. Degree: IP68
TÜV 18 ATEX 8218X
Ex II 2G Ex db IIC T6 Gb
Ex II 2D Ex tb IIIC T80°C Db
No.RU.C-DE.HA65.B.01652/22
1Ex db IIC T6 Gb
Ex tb IIIC T80°C Db
IECEx TUR18.0023X
Ex db IIC T6 Gb
Ex tb IIIC T80°C Db
* for older serial numbers please contact supportsamcon.eu
Special conditions for safe use
- The device is supplied without a cable tail and gland. The installation of suitable explosion-proof connection cable kits to the flipConnect is the responsibility of the user or can be found in the SAMCON compatibility table!
- The pre-assembled red M25 blanking plug (nylon) is not explosion-proof and is only used as an assembly tool for connecting the flipConnect!
- Use in mining areas (ATEX device Group I M2), is not permitted!
- No holes, whether blind or clear, may be drilled in the ExCam enclosure other than already provided by the manufacturer.
- The requirements of EN/IEC 60079-14 must be applied.
- All used cable glands and plugs have to be certified.
Datasheets, User Manual, Drawings, Certification, ... can be found on the product page