Scheme/market | No. | Ex-Installation Manual |
---|---|---|
ATEX Certificate | TÜV 18 ATEX 8218X (2018) | DE, EN, FR, HR |
IECEx Certificate | TUR 18.0023X (2018) | EN |
EAC-Ex TUR Report | TC RU C-DE.HA65.B.01652/22 | RU |
INMETRO Certificate | TÜV 23.0363 X | PT |
MASC Certificate | MS/18-3256X | EN |
UKEX Certificate | TÜV 22 UKEX 7137 X | EN |
PESO Certificate | EN | |
KOSHA (KCs) | actually not available | KOR |
OSHA | ML1112007038U1 | ZH |
Marking and Labeling
Model Key: T08-VA2.2.K1.BOR-L.H-***.N-P
PN: 22070478
Certification
Camera-Series T08
Luminaire-Series T20
Scheme/market | No. | Ex-Installation Manual |
---|---|---|
ATEX Certificate | TÜV 21 ATEX 8696 X (2021) | DE, EN |
IECEx Certificate | TUR 22.0076X (2022) | EN |
UKEX Certificate | TÜV 24 UKEX 7178 X (2024) | EN |
Further Certificates | upon request |
Ex-Marking ExCam
Model Key: T08-VA2.2.K1.BOR-L.H-***.N-P
PN: 22070478
Serial no.: from PT0805653*
Prod. Year: from 2023
PS: PoE+ C4, Typ.: 19.5W, Max.: 25.5W
Temp. Range: -30°C < Tamb < +50°C
Prot. Degree: IP68
TÜV 18 ATEX 8218X
Ex II 2G Ex db IIC T6 Gb
Ex II 2D Ex tb IIIC T80°C Db
No.RU.C-DE.HA65.B.01652/22
1Ex db IIC T6 Gb
Ex tb IIIC T80°C Db
IECEx TUR18.0023X
Ex db IIC T6 Gb
Ex tb IIIC T80°C Db
* for older serial numbers please contact supportsamcon.eu
Ex-Marking liteServer
Model Key: T20-VA0.1.K1.BOR-L.N-001.1-0
PN: 24060129
Serial no.: from PT0805433*
Prod. Year: from 2023
PS: 12.7W@24VDC
Temp. Range: -30°C < Tamb < +50°C
Prot. Degree: IP66/68
TÜV 21 ATEX 8696X
Ex II 2G Ex db IIC T5 Gb
Ex II 2D Ex tb IIIC T95°C Db
Ex I M2 Ex db I Mb
IECEx TUR18.0023X
Ex db IIC T5 Gb
Ex tb IIIC T80°C Db
Ex db I Mb
* for older serial numbers please contact supportsamcon.eu
Special conditions for safe use
- Use in mining areas (ATEX device Group I M2), is not permitted!
- No holes, whether blind or clear, may be drilled in the ExCam enclosure other than already provided by the manufacturer.
- The requirements of EN/IEC 60079-14 must be applied.
- All used cable glands and plugs have to be certified.
- The sight glass must not be directly covered by foreign objects. The light must be able to leave the optics of the protective housing unhindered. Regular cleaning intervals of the sight glass should be observed in order to avoid adhesion and dust deposits.
- Risk of burns from hot surfaces (≤80°C)!
- Do not stare into the direct beam. Danger of impairment of vision due to high exposure to light!
- The armoured cable bridge from ExCam to liteServer is preinstalled and must not be changed!
- The pre-installed RJ45 industrial plug may only be connected in a safe area (non-Ex zone)!
- The additional safety instructions on UA2 cam adapter of the T08/T20 device combination must be observed.
- The safety wire to protect heavy objects from falling must be attached according to the installation instructions!
Datasheets, User Manual, Drawings, Certification, ... can be found on the product page