Marking and Labeling

excam-ipm1137-le-wl-weblogo.png

Model Key: T08-VA2.2.K1.BOR-L.H-***.N-T

PN: 22070479


Certification

Camera-Series T08

icons-typenschild3.png

Luminaire-Series T20

 

Scheme/marketNo.Ex-Installation Manual
ATEX CertificateTÜV 21 ATEX 8696 X (2021)DE, EN
IECEx CertificateTUR 22.0076X (2022)EN
UKEX CertificateTÜV 24 UKEX 7178 X (2024)EN
Further Certificatesupon request

 

icons-typenschild-lite.png

Ex-Marking ExCam

Model Key: T08-VA2.2.K1.BOR-L.H-***.N-T
PN: 22070479
Serial no.: from PT0805721*
Prod. Year: from 2023
PS: PoE+ C4, Typ.: 19.5W, Max.: 25.5W
Temp. Range: -30°C < Tamb < +50°C
Prot. Degree: IP68

TÜV 18 ATEX 8218X
Ex II 2G Ex db IIC T6 Gb
Ex II 2D Ex tb IIIC T80°C Db

No.RU.C-DE.HA65.B.01652/22
1Ex db IIC T6 Gb
Ex tb IIIC T80°C Db

IECEx TUR18.0023X
Ex db IIC T6 Gb
Ex tb IIIC T80°C Db

* for older serial numbers please contact supportsamcon.eu

WARNING:
DO NOT OPEN IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Observe the safety instructions in the installation guide!

Not your language? Translate

To top

Ex-Marking liteServer

Model Key: T20-VA0.1.K1.BOR-L.N-001.1-0
PN: 24060129
Serial no.: from PT0805433*
Prod. Year: from 2023
PS: 12.7W@24VDC
Temp. Range: -30°C < Tamb < +50°C
Prot. Degree: IP66/68

TÜV 21 ATEX 8696X
Ex II 2G Ex db IIC T5 Gb
Ex II 2D Ex tb IIIC T95°C Db
Ex I M2 Ex db I Mb

IECEx TUR18.0023X
Ex db IIC T5 Gb
Ex tb IIIC T80°C Db
Ex db I Mb

* for older serial numbers please contact supportsamcon.eu

WARNING:
DO NOT OPEN IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Observe the safety instructions in the installation guide!

Not your language? Translate

To top


Special conditions for safe use

  • Use in mining areas (ATEX device Group I M2), is not permitted!
  • No holes, whether blind or clear, may be drilled in the ExCam enclosure other than already provided by the manufacturer.
  • The requirements of EN/IEC 60079-14 must be applied.
  • All used cable glands and plugs have to be certified.
  • The sight glass must not be directly covered by foreign objects. The light must be able to leave the optics of the protective housing unhindered. Regular cleaning intervals of the sight glass should be observed in order to avoid adhesion and dust deposits.
  • Risk of burns from hot surfaces (≤80°C)!
  • Do not stare into the direct beam. Danger of impairment of vision due to high exposure to light!
  • The armoured cable bridge from ExCam to liteServer is preinstalled and must not be changed!
  • The pre-installed RJ45 industrial plug may only be connected in a safe area (non-Ex zone)!
  • The additional safety instructions on UA2 cam adapter of the T08/T20 device combination must be observed.
  • The safety wire to protect heavy objects from falling must be attached according to the installation instructions!

Datasheets, User Manual, Drawings, Certification, ... can be found on the product page


Manufacturer data / certificates

SAMCON GmbH
Schillerstr. 17
35102 Lohra
Germany

Manufacturer certificates